Side & side Entry type level controller’s / Side & bottom type entry Controller’s
SIDE & SIDE TYPE CONTROLLERS
Side & Side Mounted Controller
It is normal practise to use two independent machines on each boller, one incorporating the pump switch or switches and first low- water cut-out alarm switch, the other with either one switch to provide second low- water cut-out and alarm and high-level alarm. “Usually the standard operating range is 150mm, but controllers can be supplied with 62mm, 120mm, 150mm & 250mm range”
1. CONSTRUCTION:
1.1 Chamber: ASME B36.10 (SAT06 Gr-B)
1.2Flange Connection: ASME B16.5(54105)
1.3 Working Pressure: 13 Kg/cm upto 12 kg/cm
1.4 Blow-down connections: Side entry chambers 1% BSP Parallel thread.
1.5 Float and float rod: 316 fost with 304 rod, Manel K 400 float with 304 rod.
1.6 Switch Box: Die-cast aluminum cover and base, zinc coated mild steel sheet casing.
1.7 Conduit entries. I ET IB.S.) The Switch unit mechanism has selt holding silver cadmium oxide contact and is carried on a ceramic moulding located in an aluminum die-casting.
Description Of Controllers
Product description | |
---|---|
Direct mounting Industrial Level Controllers with chamber |
Mounting flange material | ||
---|---|---|
Standard | Temp Range | |
ASME B16.5 | Carbon steel | -10 to +300 c |
Mounting flange material | |
---|---|
Standard | |
D1 | 3 IN. NB, Stainless Steel (55316) FLOAT |
D2 | 3 IN NB, MONEL FLOAT K-400 |
Mounting flange material | |
---|---|
Standard | |
Top Flange | ASME (BPVC) Sec- II (ASTMA-105) |
Cover Flange | ASME (BPVC) Sec- II (ASTMA-105 |
Branch Flange | ASME (BPVC) Sec- II (ASTMA-105 |
Chamber Pipe | ASME (BPVC) Sec- (ASTMA-106M) |
Chamber End | ASME (BPVC) Sec- II (ASTMA-105 |
5.5 Tube | ASME (BPVC) Sec-II (ASTMA-213, TP 304) |
Nuts, & Bolts | ASTMA 193 Gr-B7 |
Product Certifications | |
---|---|
Standard | |
L.B.R | Indian Boiler Regulation (Form III C) Test Certificate |
PED | Pressure Equipment Directive 2014/68/EU |
M.T.C | Manufacturing Test Certificate |
Flange Connection of Industrial level controllers | |||
---|---|---|---|
Standard | UPTO | Temp(F) | |
B.S. | Flange connection as per BS10 table H | 250 psig | 428 |
B.S. | Flange connection as per 8510 table J | 350 psig | 428 |
ASME B16.5 | Flange connection as per Class 150 | 200 psig | 300 |
ASME B16.5 | Flange connection as per Class 300 | 448 psig | 500 |
Number of switch mechanisms | |
---|---|
Standard | |
1 | One Switch |
2 | Two Switch |
3 | Three Switch |
4 | Four Switches |
5 | Five Switches |
6 | Six Switches |
Switch Mechanism Type | |
---|---|
Standard | |
SS-02/SS-05 | 4 Contact: 2X SPST (SPCO) General purpose |
SS-02/SS-05 | 4 Contact: 2 X SPST (SPCO),low power circuits |
SS-02/SS-05 | 4 Contact: 2 X SPST (SPCO),High power circuits |
SS-02/SS-05 | 8 Contact: DPDT (DPCO), General purpose |
SS-02/SS-05 | 8 Contact: DPDT (DPCO), Low power circuits |
SS-02 SS-05 | 8 Contact: DPDT (DPCO), High power circuits |